Sunday, February 14, 2010

Ceiling Styles What's The Best Way To Insulate A Single Layer Wood Ceiling?

What's the best way to insulate a single layer wood ceiling? - ceiling styles

We live in a cabin with a cathedral ceiling. Roofing materials are only between the inside and outside the house 2 "x6" language and platform roof Groove (which includes the interior of the ceiling) and the composition shingles. The roof beams 4 "x6" space of 4 meters. What can I do to increase the value of R in the house?

5 comments:

REAL SLATER said...

Whoever has this house not intend to have a temporary roof. 2x6 tongue and groove is established for the election of the permanent roofs. 2x6 and a thick layer of shale or clay enough value of R, but since you already have a ceiling of petrochemical products, there is not much you can do. When the temporary roof is new, it might be constructed and insulated from the outside from damaging his roof, but it is too late. Your only choice is really deface his house through the roof insulation and filling in some ways.

Tex said...

Roofs of this type are usually six to eight inches of rigid insulation on top of the tongue and groove, then a layer of plywood is isolated by the isolation of the tongue and groove ceiling and placed in the top screwed cons-plated. If you are a "fix and forget" solution, then you have to strip off the old shingles and do well overseas, in addition to the long run, the least expensive.

weatherization guy said...

The best way is to install 2 "thick insulation panels made of poly (4 'x 8' sheet) against existing tables, T & G (double thickness = 4), cracks in the vicinity of foam spray, then install new decorative trim. Many companies offer polyisocyanate boards, Thermax is probably the most popular. It is directly against the T & G will be installed to existing tables, or it can from the hair when you create an air space (for the distribution of high-low ... soffit) to height . A fan would also push warm air down to the ground.

ozzy said...

. 4ft.x4ft there. 1/4inch and plastic sheeting can also blow glues.they clear with a few leaves R-factor considered.i another 2 or 3 fans can .--- this Arn't limited to 1 / 4 inch shall be tested 3 / 8, 1 / 2 5 / 8;






n

Bandett said...

Google "signs of roof insulation, the only isolate them on the roof style and wait for its attractive interior than just a question of out of his car when it was built to have to cut costs.

Post a Comment